  Datasheet File OCR Text:
 Connectors (Inlets/Outlets) www.schurter.com/pg07 IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal
4787
4787
F
70 C
Description
-PanelMountScrew-onmountingfromfrontside -Connector,Pintemperature70C,ProtectionclassI -Solderterminalsorquickconnectterminals
Other versions on request References Weblinks
-Quick-connectterminals4.8x0.8mm -ForprotectionclassII GeneralProductInformation Approvals,RoHS,CHINA-RoHS,MatingConnectors,e-Store, Distributor-Stock-Check,Accessories
Approvals
-VDELicenseNumber:40009388 -ULLicenseNumber:E96454
Technical Data
RatingsIEC RatingsUL/CSA DielectricStrength 10A/250VAC;50Hz 15A/250VAC;60Hz >2kVACbetweenL-N >2kVACbetweenL/N-PE (1min/50Hz) -25Cto70C fromfrontsideIP30acc.toIEC60529 Suitableforapplianceswithprotection class1acc.toIEC61140 Solderterminalsorquickconnectterminals QuickconnectterminalsfulfilnotVDE requirements Screw:to3mm Mountingscrewtorquemax0.5Nm Thermoplastic,black,UL94V-0 40mm
AllowableOperationTemp. DegreeofProtection ProtectionClass Terminal
PanelThicknesss Material:Housing
Dimensions 4787
40.0
X
21.3
25.00
+0.20 0
22.0
20.00
+0.20 0
max.R2
6.0x90 3.2
3.0
32.0
Quick connect terminals 6.3 x 0.8 mm: x = 11.2 mm Quick connect terminals 4.8 mm: x = 9.8mm
3.2
Connectors
4787
www.schurter.com/pg07 Variants
Type 4787 4787 Panel mounting Screw Screw Panel Thickness s [mm] Terminal Quick connect terminals 4.8 x 0.8 mm Quick connect terminals 6.3 x 0.8 mm Order Number 4787.2000 4787.1000
Connectors (Inlets/Outlets)
Pleaseconsiderthemin.requiredspacingbetweenlifepartsandpossibleconductivepanel ClassIIproductsalsoavailableonrequest[4788]
Packaging unit Mating Inlets/Plugs
100Pcs
Category / Description Appliance Inlet Overview complete IEC Appliance Inlet C14, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Inlet C14, Screw-on Mounting, Rear Side, PCB Terminal IEC Appliance Inlet C14, Snap-in Mounting, Front Side, Solder or Quick-connect or Screw-on Terminal IEC Appliance Inlet C14, Screw-on Mounting, Front or Rear Side, Solder or Quick-connect or Screw-on Terminal IEC Appliance Inlet C14, Screw-on Mounting, Front or Rear Side, Solder or Quick-connect or Screw-on Terminal Appliance Inlet further types to 4787 Distribution Unit Overview complete Distribution Unit for Snap-in Mounting with 1 IEC Appliance Inlet C14 and 1 Appliance Outlet F Distribution Unit with 1 IEC Appliance Inlet C14 or Power Cord, 4 IEC Appliance Outlets F and Extra Components Distribution Unit with 1 IEC Appliance Inlet C14 and 2 Appliance Outlets F, Shuttered Distribution Unit with 1 IEC Appliance Inlet C14 and 4 Appliance Outlets F Distribution Unit further types to 4787 Interconnection Cord Overview complete Interconnection Cord with IEC Plug E, Angled Interconnection Cord with IEC Plug E, Angled Interconnection Cord with IEC Plug E, Straight Interconnection Cord with IEC Plug G, Angled Interconnection Cord with IEC Plug G, Angled Interconnection Cord further types to 4787 Plug Overview complete IEC Plug E, Cord Connector (Rewireable), Straight, max. cable Diameter 8.5 mm IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm IEC Plug E, Cord Connector (Rewireable), Straight, max. Cable Diameter 10 mm IEC Plug E, Cord Connector (Rewireable), Angled, max. Cable Diameter 10 mm IEC Plug E, Cord Connector (Rewireable), Straight Plug further types to 4787 Power Entry Module Overview complete IEC Appliance Inlet C14 or C18 with Fuseholder 1-pole IEC Appliance Inlet C14 or C18 with Fuseholder 1- or 2-pole IEC Appliance Inlet C14 with Fuseholder 1- or 2-pole IEC Appliance Inlet C14 with Line Switch 1- or 2-pole IEC Appliance Inlet C14 with Circuit Breaker TA35 2-pole Power Entry Module further types to 4787 Power Entry Module with line filter Overview complete IEC Appliance Inlet C14 with Filter IEC Appliance Inlet C14 with Filter, Circuit Breaker TA45 IEC Appliance Inlet C14 with Filter, Fuseholder 1-pole IEC Appliance Inlet C14 with Filter, Fuseholder 1- or 2-pole IEC Appliance Inlet C14 with Filter, Fuseholder 2-pole Power Entry Module with line filter further types to 4787 5110 5145 5200 5220 8843-8 ... 1062 1064 1092 6010-K 6135 ... 4732 4733 4735 4736 9009 ... 0607 0608 0609 607B 608B ... 0712 4740 4741 4747 0711 1001 6010 6048 6049 ...
Thespecifications,descriptionsandillustrationsindicatedinthisdocumentarebasedon Connectors currentinformation.Allcontentissubjecttomodificationsandamendments.